Metadata-Version: 2.1
Name: sunpower-pvs-exporter
Version: 1.0
Summary: A Prometheus Exporter for the SunPower PVS Device
Home-page: https://github.com/ginoledesma/sunpower-pvs-exporter/
Author: Gino Ledesma
Author-email: gledesma@gmail.com
License: MIT
Description: About
        =====
        
        A Prometheus exporter for the SunPower ProVision monitoring system:
        
        - SunPower PVS 5x
        - SunPower PVS 6
        
        Requirements
        ============
        
        - Python 2.7+
        - Prometheus Client
        
        Installation
        ============
        
        From pip:
        ```
        pip install sunpower_pvs_exporter
        ```
        
        From github:
        ```
        # pip install git@github.apple.com:ginoledesma/sunpower-pvs-exporter.git
        pip install sunpower_pvs_exporter
        ```
        
        Usage
        =====
        
        
        Help
        ----
        ```
        $ sunpower-pvs-exporter -h 
        usage: sunpower-pvs-exporter [-h] [--hostname HOSTNAME] [--port PORT]
                                     [--use-tls] [--listen-on LISTEN_ON]
                                     [--log-file LOG_FILE]
                                     [--log-level {ERROR,WARNING,INFO,DEBUG}]
                                     [--timeout TIMEOUT] [--use-device-data-timestamp]
        
        optional arguments:
          -h, --help            show this help message and exit
          --hostname HOSTNAME   SunPower PV Supervisor hostname
          --port PORT           SunPower PV Supervisor port
          --use-tls             Use SSL/TLS when communicating with SunPower PV
                                Supervisor
          --listen-on LISTEN_ON
                                Listen on the specified port
          --log-file LOG_FILE   Output logfile
          --log-level {ERROR,WARNING,INFO,DEBUG}
                                Log level
          --timeout TIMEOUT     Connection timeout value (in seconds)
          --use-device-data-timestamp
                                Use the data timestamp from the PVS device
        ```
        
        Runtime 
        -------
        ```
        $ sunpower-pvs-exporter
        2019-05-13 20:13:48,701 Listening on port 9110...
        
        $ curl http://localhost:9110/
        # HELP python_info Python platform information
        # TYPE python_info gauge
        python_info{implementation="CPython",major="2",minor="7",patchlevel="10",version="2.7.10"} 1.0
        # HELP sunpower_pvs_communication_interface_info Communications Interface Information
        # TYPE sunpower_pvs_communication_interface_info gauge
        sunpower_pvs_communication_interface_info{interface="wan",internet="up",sms="reachable"} 1.0
        sunpower_pvs_communication_interface_info{interface="plc",internet="down",sms="unreachable"} 1.0
        sunpower_pvs_communication_interface_info{interface="sta0",internet="down",sms="unreachable"} 1.0
        sunpower_pvs_communication_interface_info{interface="cell",internet="down",sms="unreachable"} 1.0
        # HELP sunpower_pvs_grid_profile_info Grid Profile
        # TYPE sunpower_pvs_grid_profile_info gauge
        sunpower_pvs_grid_profile_info{id="aabbccddeeffaabbccddeeffaabbccddeeffaabbccd",name="IEEE-1547",percent="100",status="success"} 1.0
        # HELP sunpower_pvs_supervisor_communication_errors_total Total number of communication errors
        # TYPE sunpower_pvs_supervisor_communication_errors_total counter
        sunpower_pvs_supervisor_communication_errors_total{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 283.0
        # HELP sunpower_pvs_supervisor_cpu_loadavg CPU Load Average
        # TYPE sunpower_pvs_supervisor_cpu_loadavg gauge
        sunpower_pvs_supervisor_cpu_loadavg{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 0.2
        # HELP sunpower_pvs_supervisor_errors_total Total number of errors
        # TYPE sunpower_pvs_supervisor_errors_total counter
        sunpower_pvs_supervisor_errors_total{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 0.0
        # HELP sunpower_pvs_supervisor_flash_storage_available_bytes Storage available space (bytes)
        # TYPE sunpower_pvs_supervisor_flash_storage_available_bytes gauge
        sunpower_pvs_supervisor_flash_storage_available_bytes{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 7.8512128e+07
        # HELP sunpower_pvs_supervisor_mem_used_bytes Memory used (bytes)
        # TYPE sunpower_pvs_supervisor_mem_used_bytes gauge
        sunpower_pvs_supervisor_mem_used_bytes{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 3.9350272e+07
        # HELP sunpower_pvs_supervisor_scan_time_seconds Scan time
        # TYPE sunpower_pvs_supervisor_scan_time_seconds gauge
        sunpower_pvs_supervisor_scan_time_seconds{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 0.0
        # HELP sunpower_pvs_supervisor_skipped_scans_total Skipped scans
        # TYPE sunpower_pvs_supervisor_skipped_scans_total counter
        sunpower_pvs_supervisor_skipped_scans_total{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 0.0
        # HELP sunpower_pvs_supervisor_untransmitted_events_total Untransmitted events
        # TYPE sunpower_pvs_supervisor_untransmitted_events_total counter
        sunpower_pvs_supervisor_untransmitted_events_total{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 9510.0
        # HELP sunpower_pvs_supervisor_uptime_seconds_total Uptime (seconds)
        # TYPE sunpower_pvs_supervisor_uptime_seconds_total counter
        sunpower_pvs_supervisor_uptime_seconds_total{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 10494.0
        # HELP sunpower_pvs_power_meter_ct_rated_current_amperes CT Rated Current
        # TYPE sunpower_pvs_power_meter_ct_rated_current_amperes gauge
        sunpower_pvs_power_meter_ct_rated_current_amperes{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 50.0
        sunpower_pvs_power_meter_ct_rated_current_amperes{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} 100.0
        # HELP sunpower_pvs_power_meter_ac_frequency_hertz AC Frequency
        # TYPE sunpower_pvs_power_meter_ac_frequency_hertz gauge
        sunpower_pvs_power_meter_ac_frequency_hertz{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 60.0
        sunpower_pvs_power_meter_ac_frequency_hertz{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} 60.0
        # HELP sunpower_pvs_power_meter_net_energy_watt_hours Total Net Energy
        # TYPE sunpower_pvs_power_meter_net_energy_watt_hours gauge
        sunpower_pvs_power_meter_net_energy_watt_hours{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 294370.0
        sunpower_pvs_power_meter_net_energy_watt_hours{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} -103980.0
        # HELP sunpower_pvs_power_meter_average_real_power_watts Average real power
        # TYPE sunpower_pvs_power_meter_average_real_power_watts gauge
        sunpower_pvs_power_meter_average_real_power_watts{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 9.0
        sunpower_pvs_power_meter_average_real_power_watts{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} 464.1
        # HELP sunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive Average reactive power
        # TYPE sunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive gauge
        sunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 328.0
        sunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} -915.6
        # HELP sunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive Average reactive power
        # TYPE sunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive gauge
        sunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 329.40000000000003
        sunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} 1077.3999999999999
        # HELP sunpower_pvs_power_meter_power_factor_real_power_per_apparent_power Power Factor (Real Power / Apparent Power) ratio
        # TYPE sunpower_pvs_power_meter_power_factor_real_power_per_apparent_power gauge
        sunpower_pvs_power_meter_power_factor_real_power_per_apparent_power{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 0.0241
        sunpower_pvs_power_meter_power_factor_real_power_per_apparent_power{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} 0.4302
        # HELP sunpower_pvs_inverter_ac_current_amperes AC Current
        # TYPE sunpower_pvs_inverter_ac_current_amperes gauge
        sunpower_pvs_inverter_ac_current_amperes{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 0.0
        sunpower_pvs_inverter_ac_current_amperes{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 0.0
        sunpower_pvs_inverter_ac_current_amperes{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 0.0
        # HELP sunpower_pvs_inverter_ac_power_watts AC Power
        # TYPE sunpower_pvs_inverter_ac_power_watts gauge
        sunpower_pvs_inverter_ac_power_watts{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 0.1
        sunpower_pvs_inverter_ac_power_watts{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 0.4
        sunpower_pvs_inverter_ac_power_watts{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 0.0
        # HELP sunpower_pvs_inverter_ac_voltage_volts AC Voltage
        # TYPE sunpower_pvs_inverter_ac_voltage_volts gauge
        sunpower_pvs_inverter_ac_voltage_volts{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 250.48
        sunpower_pvs_inverter_ac_voltage_volts{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 249.98
        sunpower_pvs_inverter_ac_voltage_volts{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 250.16
        # HELP sunpower_pvs_inverter_dc_current_amperes DC Current
        # TYPE sunpower_pvs_inverter_dc_current_amperes gauge
        sunpower_pvs_inverter_dc_current_amperes{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 0.01
        sunpower_pvs_inverter_dc_current_amperes{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 0.03
        sunpower_pvs_inverter_dc_current_amperes{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 0.03
        # HELP sunpower_pvs_inverter_dc_power_watts DC Power
        # TYPE sunpower_pvs_inverter_dc_power_watts gauge
        sunpower_pvs_inverter_dc_power_watts{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 0.1
        sunpower_pvs_inverter_dc_power_watts{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 0.6
        sunpower_pvs_inverter_dc_power_watts{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 0.8
        # HELP sunpower_pvs_inverter_dc_voltage_volts DC Voltage
        # TYPE sunpower_pvs_inverter_dc_voltage_volts gauge
        sunpower_pvs_inverter_dc_voltage_volts{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 10.12
        sunpower_pvs_inverter_dc_voltage_volts{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 21.99
        sunpower_pvs_inverter_dc_voltage_volts{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 21.99
        # HELP sunpower_pvs_inverter_operating_frequency_hertz Operating Frequency (hertz)
        # TYPE sunpower_pvs_inverter_operating_frequency_hertz gauge
        sunpower_pvs_inverter_operating_frequency_hertz{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 60.19
        sunpower_pvs_inverter_operating_frequency_hertz{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 59.98
        sunpower_pvs_inverter_operating_frequency_hertz{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 59.98
        # HELP sunpower_pvs_inverter_energy_total_watt_hours Total Energy
        # TYPE sunpower_pvs_inverter_energy_total_watt_hours gauge
        sunpower_pvs_inverter_energy_total_watt_hours{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 19249.9
        sunpower_pvs_inverter_energy_total_watt_hours{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 19313.7
        sunpower_pvs_inverter_energy_total_watt_hours{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 18932.5
        # HELP sunpower_pvs_inverter_heatsink_temperature_celcius Heatsink Temperature
        # TYPE sunpower_pvs_inverter_heatsink_temperature_celcius gauge
        sunpower_pvs_inverter_heatsink_temperature_celcius{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 22.0
        sunpower_pvs_inverter_heatsink_temperature_celcius{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 22.0
        sunpower_pvs_inverter_heatsink_temperature_celcius{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 21.0
        # HELP sunpower_pvs_device_state Device (Component/Module) State
        # TYPE sunpower_pvs_device_state gauge
        sunpower_pvs_device_state{device_id="ZT01234567890123456",device_type="PVS",model="PV Supervisor PVS6",software_version="2019.5, Build 4150",state="working",type=""} 1.0
        sunpower_pvs_device_state{device_id="PVS6M01234567p",device_type="Power Meter",model="PVS6M0001p",software_version="3000",state="working",type="PVS5-METER-P"} 1.0
        sunpower_pvs_device_state{device_id="PVS6M01234567c",device_type="Power Meter",model="PVS6M0001c",software_version="3000",state="working",type="PVS5-METER-C"} 1.0
        sunpower_pvs_device_state{device_id="E00000000000001",device_type="Inverter",model="AC_Module_Type_E",software_version="118079776",state="working",type="SOLARBRIDGE"} 1.0
        sunpower_pvs_device_state{device_id="E00000000000002",device_type="Inverter",model="AC_Module_Type_E",software_version="118079776",state="working",type="SOLARBRIDGE"} 1.0
        sunpower_pvs_device_state{device_id="E00000000000003",device_type="Inverter",model="AC_Module_Type_E",software_version="118079776",state="working",type="SOLARBRIDGE"} 1.0
        ```
        
        The `--use-device-data-timestamp` flag causes the exporter to use the 
        timestamp emitted from the PVS device. This is disabled by default for a few 
        reasons:
        
        * Setting the timestamp explicitly (instead of having Prometheus do it) is 
        best suited for the [Push Gateway](https://prometheus.io/docs/practices/pushing/)
        
        * Depending on the component, the timestamp value may be too "out-of-date" 
        (for example, the Supervisor component refreshes once every 5 minutes only)
        
        * The timestamp field may not be available when the device is in an error state
        
        References
        ----------
        
        See the [Notes](sunpower_pvs_notes.md) section for more information.
        
        
        Example Grafana Dashboards
        --------------------------
        
        ![Summary Dashboard](docs/summary_screen.png) - [Panel Config](docs/summary_panel_config.json)
        ![Inverter Dashboard](docs/inverter_screen.png) - [Panel Config](docs/inverter_panel_config.json)
        ![PVS Supervisor Dashboard](docs/pvs_supervisor_panel_config.png) - [Panel Config](docs/pvs_supervisor_panel_config.json) 
        
Keywords: sunpower pvs prometheus exporter
Platform: UNKNOWN
Classifier: Environment :: Console
Classifier: License :: OSI Approved :: MIT License
Classifier: Environment :: Web Environment
Classifier: Intended Audience :: Developers
Classifier: Programming Language :: Python :: 2
Classifier: Programming Language :: Python :: 2.7
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.4
Classifier: Programming Language :: Python :: 3.5
Classifier: Programming Language :: Python :: 3.6
Requires-Python: >=2.7
Description-Content-Type: text/markdown