More data inspection
********************
IntelHex provides some metadata about the hex file it contains. 
To obtain address limits use methods ``.minaddr()`` and ``.maxaddr()``. 
These are computed based on the lowest and highest used memory spaces 
respectively.

Some linkers write to produced HEX file information about start address 
(either record 03 or 05). IntelHex is able correctly read such records 
and store information internally in ``start_addr`` attribute that itself 
is either ``None`` or a dictionary with the address value(s).

When input HEX file contains record type 03 (Start Segment Address Record), 
``start_addr`` takes value::

    {'CS': XXX, 'IP': YYY}

Here:

* ``XXX`` is value of CS register
* ``YYY`` is value of IP register

To obtain or change ``CS`` or ``IP`` value you need to use their names as keys 
for ``start_addr`` dictionary::

    >>> ih = IntelHex('file_with_03.hex')
    >>> print ih.start_addr['CS']
    >>> print ih.start_addr['IP']

When input HEX file contains record type 05 (Start Linear Address Record), 
``start_addr`` takes value::

    {'EIP': ZZZ}

Here ``ZZZ`` is value of EIP register.

Example::

    >>> ih = IntelHex('file_with_05.hex')
    >>> print ih.start_addr['EIP']

You can manually set required start address::

    >>> ih.start_addr = {'CS': 0x1234, 'IP': 0x5678}
    >>> ih.start_addr = {'EIP': 0x12345678}

To delete start address info give value ``None`` or empty dictionary::

    >>> ih.start_addr = None
    >>> ih.start_addr = {}

When you write data to HEX file you can disable writing start address 
with additional argument ``write_start_addr``::

    >>> ih.write_hex_file('out.hex') # by default writing start address
    >>> ih.write_hex_file('out.hex', True) # as above
    >>> ih.write_hex_file('out.hex', False) # don't write start address

When ``start_addr`` is ``None`` or an empty dictionary nothing will be written 
regardless of ``write_start_addr`` argument value.

For more information about start address, please see the Intel Hex file format 
specification.

Because Intel Hex files do not specify every location in memory, 
it is necessary to have a padding byte defined. Whenever a read is attempted 
from an address that is unspecified, the padding byte is returned. 
This default data is set via attribute ``.padding`` of class instance. 
This defaults to '0xFF', but it can be changed by the user like so::

    >>> print ih[0]       # prints 0xFF because this location is blank
    >>> ih.padding = 0x00 # change padding byte
    >>> print ih[0]       # prints 0x00 because this location is blank