Metadata-Version: 2.1
Name: intouch-client
Version: 0.2.4.post0
Summary: A aiohttp-based client for Intergas Intouch Lan2RF systems
Home-page: https://github.com/zxdavb/intouch-client
Author: David Bonnes
Author-email: zxdavb@gmail.com
License: UNKNOWN
Download-URL: https://github.com/zxdavb/intouch-client/archive/VERSION.tar.gz
Description: # DEPRECATED
        
        This package has been deprecated in favour of [incomfort-client](https://pypi.org/project/incomfort-client/)
        
        # intouch-client
        
        Python client library for **Intergas InTouch-compatible boilers** accesible via a **Lan2RF gateway**. It includes a basic CLI to demonstrate how to use the library.
        
        ### Porting from syncio libraries
        This library is based upon https://github.com/bwesterb/incomfort, but uses **aiohttp** rather than synchronous I/O (such as **requests** or **httplib**).
        
        Where possible, it uses uses the same methods and properties as **incomfort**, but with the following differences:
        
          - `InTouchGateway` class renamed from Gateway
            - added kwargs: `username`, `password` (used for later versions of firmware)
        
          - `InTouchHeater` class renamed from Heater
            - renamed: `is_burning`, `is_failed`, `is_pumping`, `is_tapping`
            - moved out: `room_temp`, `setpoint`, `setpoint_override`, `set`
            - new/added: `update`, `status`, `rooms`
        
          - `InTouchRoom` class has been added, and some methods moved in from Heater
            - same name: `room_temp`, `setpoint`
            - renamed: `override`, `set_override`
            - new/added: `status`
        
        ### Basic CLI included
        There is a very basic CLI (the output has been formatted here for readability):
        ```bash
        (venv) root@hostname:~/client_apis/intouch-client$ python intouchclient/__init__.py ${HOSTNAME}
        {
          'display_code': 126,
          'display_text': 'standby',
          'fault_code': 0,
        
          'is_burning': False,
          'is_failed': False,
          'is_pumping': False,
          'is_tapping': False,
        
          'heater_temp': 31.22,
          'tap_temp': 27.91,
          'pressure': 1.23,
          'serial_no': '175t23072',
        
          'nodenr': 200,
          'rf_message_rssi': 38,
          'rfstatus_cntr': 0,
        
          'room_1': {'room_temp': 26.4, 'setpoint': 19.5, 'override': 19.5},
          'room_2': {'room_temp': None, 'setpoint': None, 'override': 19.0}
        }
        ```
        
Keywords: intergas,intouch,lan2rf
Platform: UNKNOWN
Classifier: Programming Language :: Python :: 3
Classifier: License :: OSI Approved :: MIT License
Classifier: Operating System :: OS Independent
Classifier: Development Status :: 7 - Inactive
Description-Content-Type: text/markdown