Metadata-Version: 2.1
Name: pywibeee
Version: 0.0.2
Summary: Command line interface (CLI) for WiBeee (old Mirubee) meter
Home-page: https://github.com/fquinto/pywibeee
Author: fquinto
Author-email: fran.quinto@gmail.com
License: License :: OSI Approved :: GNU General Public License v2 (GPLv2)
Description: # pywibeee
        
        Command line interface (CLI) for WiBeee (old Mirubee) meter.
        
        ## Features
        
        - Autodiscover the host (IP) of the meter in a network
        - Get version of the meter
        - Get model of the meter
        - Get info of the meter: (version + model + host)
        - Get status meter data
        - Get sensors of the meter
        - Action: reset energy counter
        - Action: reboot of the meter (via web or via special command)
        - Several outputs when recieve data: xml, json, file, plain text
        
        ## Requirements
        
        `pip install xmltodict requests`
        
        # Installation
        
        Install Python CLI package [pywibeee](https://pypi.org/project/pywibeee/)
        
        ```
        $ pip install pywibeee --upgrade
        ```
        
        # Usage
        
        ```
        $ pywibeee -h
        
        usage: pywibeee [-h] [-version] (--host HOST | --auto) [-t SETTIMEOUT]
                        [-o {xml,json,plain,file}]
                        (-a {reboot,rebootweb,resetenergy} | -g {model,version,status,info,sensors})
        
        CLI for WiBeee (old Mirubee) meter
        
        optional arguments:
          -h, --help            show this help message and exit
          -version, --version   show program's version number and exit
          --host HOST           The host (or the IP) of the meter.
          --auto                Autodiscover host function, look IP on net.
          -t SETTIMEOUT, --settimeout SETTIMEOUT
                                set timeout in seconds (default 10)
          -o {xml,json,plain,file}, --output {xml,json,plain,file}
                                xml|json|plain|file
          -a {reboot,rebootweb,resetenergy}, --action {reboot,rebootweb,resetenergy}
                                reboot|rebootweb|resetenergy
          -g {model,version,status,info,sensors}, --get {model,version,status,info,sensors}
                                model|version|status|info|sensors
        
        Enjoy! :)
        ```
        
        ## Use examples
        
        ### Get version
        
        ```
        $ pywibeee --host 192.168.1.150 --get version
        {"response": {"webversion": "3.4.614"}}
        ```
        
        ### Get model
        
        ```
        $ pywibeee --host 192.168.1.150 --get model
        {"response": {"model": "WBB", "model_description": "Wibeee BOX"}}
        ```
        
        ### Get info
        
        ```
        $ pywibeee --host 192.168.1.150 -g info
        {"response": {"model": "WBB", "model_description": "Wibeee BOX", "webversion": "3.4.614", "host": "192.168.1.150"}}
        ```
        
        ### Get sensors with autodiscover
        
        ```
        $ pywibeee --auto -g sensors
        {"vrms": ["Vrms", "V", "mdi:power-plug"], "irms": ["Irms", "A", "mdi:flash-auto"], "p_aparent": ["Apparent Power", "VA", "mdi:flash-circle"], "p_activa": ["Active Power", "W", "mdi:flash"], "p_reactiva_ind": ["Inductive Reactive Power", "VArL", "mdi:flash-outline"], "p_reactiva_cap": ["Capacitive Reactive Power", "VArC", "mdi:flash-outline"], "frecuencia": ["Frequency", "Hz", "mdi:current-ac"], "factor_potencia": ["Power Factor", " ", "mdi:math-cos"], "energia_activa": ["Active Energy", "Wh", "mdi:pulse"], "energia_reactiva_ind": ["Inductive Reactive Energy", "VArLh", "mdi:alpha-e-circle-outline"], "energia_reactiva_cap": ["Capacitive Reactive Energy", "VArCh", "mdi:alpha-e-circle-outline"], "angle": ["Angle", "\u00b0", "mdi:angle-acute"], "thd_total": ["THD Current", "%", "mdi:chart-bubble"], "thd_fund": ["THD Current (fundamental)", "A", "mdi:vector-point"], "thd_ar3": ["THD Current Harmonic 3", "A", "mdi:numeric-3"], "thd_ar5": ["THD Current Harmonic 5", "A", "mdi:numeric-5"], "thd_ar7": ["THD Current Harmonic 7", "A", "mdi:numeric-7"], "thd_ar9": ["THD Current Harmonic 9", "A", "mdi:numeric-9"], "thd_tot_V": ["THD Voltage", "%", "mdi:chart-bubble"], "thd_fun_V": ["THD Voltage (fundamental)", "V", "mdi:vector-point"], "thd_ar3_V": ["THD Voltage Harmonic 3", "V", "mdi:numeric-3"], "thd_ar5_V": ["THD Voltage Harmonic 5", "V", "mdi:numeric-5"], "thd_ar7_V": ["THD Voltage Harmonic 7", "V", "mdi:numeric-7"], "thd_ar9_V": ["THD Voltage Harmonic 9", "V", "mdi:numeric-9"]}
        ```
        
        ### Get status
        
        ```
        $ pywibeee --host 192.168.1.150 --get status
        {"response": {"model": "WBB", "webversion": "3.4.614", "time": "1570484447", "fase1_vrms": "228.70", "fase1_irms": "1.59", "fase1_p_aparent": "362.65", "fase1_p_activa": "264.34", "fase1_p_reactiva_ind": "0.00", "fase1_p_reactiva_cap": "248.27", "fase1_frecuencia": "50.08", "fase1_factor_potencia": "-0.729", "fase1_energia_activa": "222157", "fase1_energia_reactiva_ind": "4631", "fase1_energia_reactiva_cap": "188269", "fase1_angle": "0.00", "fase1_thd_total": "64.60", "fase1_thd_fund": "1.40", "fase1_thd_ar3": "0.60", "fase1_thd_ar5": "0.50", "fase1_thd_ar7": "0.40", "fase1_thd_ar9": "0.40", "fase1_thd_tot_V": "0.00", "fase1_thd_fun_V": "228.50", "fase1_thd_ar3_V": "0.00", "fase1_thd_ar5_V": "0.00", "fase1_thd_ar7_V": "0.00", "fase1_thd_ar9_V": "0.00", "fase2_vrms": "228.70", "fase2_irms": "0.34", "fase2_p_aparent": "76.77", "fase2_p_activa": "50.99", "fase2_p_reactiva_ind": "0.00", "fase2_p_reactiva_cap": "0.00", "fase2_frecuencia": "50.08", "fase2_factor_potencia": "-0.664", "fase2_energia_activa": "47714", "fase2_energia_reactiva_ind": "5021", "fase2_energia_reactiva_cap": "641", "fase2_angle": "0.00", "fase2_thd_total": "0.00", "fase2_thd_fund": "0.00", "fase2_thd_ar3": "0.00", "fase2_thd_ar5": "0.00", "fase2_thd_ar7": "0.00", "fase2_thd_ar9": "0.00", "fase2_thd_tot_V": "0.00", "fase2_thd_fun_V": "228.50", "fase2_thd_ar3_V": "0.00", "fase2_thd_ar5_V": "0.00", "fase2_thd_ar7_V": "0.00", "fase2_thd_ar9_V": "0.00", "fase3_vrms": "228.70", "fase3_irms": "1.53", "fase3_p_aparent": "349.48", "fase3_p_activa": "265.40", "fase3_p_reactiva_ind": "0.00", "fase3_p_reactiva_cap": "227.37", "fase3_frecuencia": "50.08", "fase3_factor_potencia": "0.759", "fase3_energia_activa": "187069", "fase3_energia_reactiva_ind": "196", "fase3_energia_reactiva_cap": "159927", "fase3_angle": "0.00", "fase3_thd_total": "66.10", "fase3_thd_fund": "1.30", "fase3_thd_ar3": "0.60", "fase3_thd_ar5": "0.50", "fase3_thd_ar7": "0.40", "fase3_thd_ar9": "0.00", "fase3_thd_tot_V": "0.00", "fase3_thd_fun_V": "228.50", "fase3_thd_ar3_V": "0.00", "fase3_thd_ar5_V": "0.00", "fase3_thd_ar7_V": "0.00", "fase3_thd_ar9_V": "0.00", "fase4_vrms": "228.70", "fase4_irms": "3.45", "fase4_p_aparent": "788.90", "fase4_p_activa": "49.93", "fase4_p_reactiva_ind": "0.00", "fase4_p_reactiva_cap": "20.90", "fase4_frecuencia": "50.08", "fase4_factor_potencia": "-0.063", "fase4_energia_activa": "456941", "fase4_energia_reactiva_ind": "9849", "fase4_energia_reactiva_cap": "348839", "scale": "100", "coilStatus": null, "ground": "0.00", "model_description": "Wibeee BOX"}}
        ```
        
        # Notes
        
        - Default IP for WiBeee (old Mirubee): 192.168.1.150
        - Default usernames / passwords:
            - Basic: `user / user`
            - Admin: `admin / Sm1l1cs?`
            - Admin another: `admin / Wib333?`
        - OTA comands: WbStartBootloaderProccess, WbFinishBootloaderProccess
        - Last (11/09/2019) OTA firmware file url: https://app.mirubee.com/api/fw/wbb/FOTAFile_V3.4.614_WBB.bin
            - MD5: 57d8c4a3c77e510fe0ae6ff44cdb7afc
        
        # Models description WiBeee
        
         - WBM = Wibeee 1Ph
         - WBT = Wibeee 3Ph
         - WMX = Wibeee MAX
         - WTD = Wibeee 3Ph RN
         - WX2 = Wibeee MAX 2S
         - WX3 = Wibeee MAX 3S
         - WXX = Wibeee MAX MS
         - WBB = Wibeee BOX
         - WB3 = Wibeee BOX S3P
         - W3P = Wibeee 3Ph 3W
         - WGD = Wibeee GND
         - WBP = Wibeee SMART PLUG
        
        # Installation alternatives (getting latest source code)
        
        If you want to install latest source code:
        
        `$ pip install git+http://github.com/fquinto/pywibeee`
        
        or
        
        ```
        $ git clone git://github.com/fquinto/pywibeee
        $ cd pywibeee
        $ python setup.py install
        ```
        
        # Changelog
        
        - 0.0.1 First draft functional version.
        - 0.0.2 Improve json output. Remove dependency jxmlease. New dependency xmltodict. Added model description.
        
        # Future development
        
        - Improve another models.
        
        # Development CLI for Python references
        
        - https://realpython.com/command-line-interfaces-python-argparse/
        
        
        - `pip3 install --user pipenv`
        - `pipenv install requests`
        - `pipenv install xmltodict`
        
        ```
        pipenv shell
        pipenv run
        ```
        
        ## Generating distribution archives
        
        - `python3 -m pip install --user --upgrade setuptools wheel`
        - `python3 setup.py sdist bdist_wheel`
        - `python setup.py sdist`
        - `python -m pip install .`
        - `python tests/test_project.py`
        
        # License
        
        GNU General Public License version 2
        
        - https://www.gnu.org/licenses/old-licenses/gpl-2.0.html
        - https://choosealicense.com/licenses/gpl-2.0/
        - https://opensource.org/licenses/GPL-2.0
        
Keywords: cli interface wibeee mirubeee meter hass
Platform: UNKNOWN
Classifier: Programming Language :: Python
Classifier: Programming Language :: Python :: 3
Classifier: Operating System :: OS Independent
Classifier: License :: OSI Approved :: GNU General Public License v2 (GPLv2)
Classifier: Topic :: Home Automation
Classifier: Topic :: System :: Monitoring
Classifier: Topic :: System :: Shells
Classifier: Development Status :: 5 - Production/Stable
Classifier: Environment :: Console
Classifier: Intended Audience :: End Users/Desktop
Classifier: Intended Audience :: Developers
Requires-Python: >=3.5
Description-Content-Type: text/markdown